The resolution of the uv_hrtime() function is bigger than the
intervals used in the timers, which can result in an unexpected
difference between the start_time and stop_time variables.
Use isc_loop_now(), which is based on uv_now() and has the same
milliseconds resolution as the functions in the uv_timer_t API.
Also fix a couple wrong numbers in the comments.