diff --git a/bin/named/named.8 b/bin/named/named.8
index 340840360f..bc8832a869 100644
--- a/bin/named/named.8
+++ b/bin/named/named.8
@@ -1,4 +1,4 @@
-.\" Copyright (C) 2004-2008 Internet Systems Consortium, Inc. ("ISC")
+.\" Copyright (C) 2004-2009 Internet Systems Consortium, Inc. ("ISC")
.\" Copyright (C) 2000, 2001, 2003 Internet Software Consortium.
.\"
.\" Permission to use, copy, modify, and distribute this software for any
@@ -13,18 +13,18 @@
.\" OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
.\" PERFORMANCE OF THIS SOFTWARE.
.\"
-.\" $Id: named.8,v 1.38 2008/11/07 01:11:19 tbox Exp $
+.\" $Id: named.8,v 1.39 2009/05/22 01:14:49 tbox Exp $
.\"
.hy 0
.ad l
.\" Title: named
.\" Author:
.\" Generator: DocBook XSL Stylesheets v1.71.1
named [-4] [-6] [-c ] [config-file-d ] [debug-level-f] [-g] [-m ] [flag-n ] [#cpus-p ] [port-s] [-S ] [#max-socks-t ] [directory-u ] [user-v] [-V] [-x ]cache-file
named is a Domain Name System (DNS) server, part of the BIND 9 distribution from ISC. For more @@ -47,7 +47,7 @@
In routine operation, signals should not be used to control the nameserver; rndc should be used @@ -241,16 +241,24 @@
The named configuration file is too complex to describe in detail here. A complete description is provided in the BIND 9 Administrator Reference Manual.
+
+ named inherits the umask
+ (file creation mode mask) from the parent process. If files
+ created by named, such as journal files,
+ need to have custom permissions, the umask
+ should be set explicitly in the script used to start the
+ named process.
+
named [-4] [-6] [-c ] [config-file-d ] [debug-level-f] [-g] [-m ] [flag-n ] [#cpus-p ] [port-s] [-S ] [#max-socks-t ] [directory-u ] [user-v] [-V] [-x ]cache-file
named is a Domain Name System (DNS) server, part of the BIND 9 distribution from ISC. For more @@ -65,7 +65,7 @@
In routine operation, signals should not be used to control the nameserver; rndc should be used @@ -259,16 +259,24 @@
The named configuration file is too complex to describe in detail here. A complete description is provided in the BIND 9 Administrator Reference Manual.
+
+ named inherits the umask
+ (file creation mode mask) from the parent process. If files
+ created by named, such as journal files,
+ need to have custom permissions, the umask
+ should be set explicitly in the script used to start the
+ named process.
+
nsupdate [-d] [-D] [[-g] | [-o] | [-y ] | [[hmac:]keyname:secret-k ]] [keyfile-t ] [timeout-u ] [udptimeout-r ] [udpretries-R ] [randomdev-v] [filename]
nsupdate is used to submit Dynamic DNS Update requests as defined in RFC2136 to a name server. @@ -187,7 +187,7 @@
The TSIG key is redundantly stored in two separate files. This is a consequence of nsupdate using the DST library diff --git a/doc/arm/man.rndc-confgen.html b/doc/arm/man.rndc-confgen.html index 000021b4dd..71ad32c668 100644 --- a/doc/arm/man.rndc-confgen.html +++ b/doc/arm/man.rndc-confgen.html @@ -14,7 +14,7 @@ - OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR - PERFORMANCE OF THIS SOFTWARE. --> - +
@@ -48,7 +48,7 @@rndc-confgen [-a] [-b ] [keysize-c ] [keyfile-h] [-k ] [keyname-p ] [port-r ] [randomfile-s ] [address-t ] [chrootdir-u ]user
rndc-confgen generates configuration files for rndc. It can be used as a @@ -64,7 +64,7 @@
rndc.conf
rndc.conf is the configuration file
for rndc, the BIND 9 name server control
utility. This file has a similar structure and syntax to
@@ -135,7 +135,7 @@
The name server must be configured to accept rndc connections and
to recognize the key specified in the rndc.conf
@@ -219,7 +219,7 @@
rndc [-b ] [source-address-c ] [config-file-k ] [key-file-s ] [server-p ] [port-V] [-y ] {command}key_id